Showing posts with label First Vision. Show all posts
Showing posts with label First Vision. Show all posts

Tuesday, October 1, 2013

Notifier FirstVision Touchscreen Annunciator

Notifier FirstVision

Notifier ONYX Series FirstVision

For a while now, Notifier has had a beautiful touchscreen fire alarm annunciator titled ONYX FirstVisionFirstVision annunciator they will be able to quickly and accurately locate the device(s) in alarm.  With that said, the programmer and system installer can also distinguish valuable information right on the First Vision screen.  Information such as what types of potential hazards are located in the rooms.  Is there paint, gas, chemicals?  Before it was almost impossible to know.  Notifier has now outdone themselves once again with this beautiful and effective FirstVision fire alarm annunciator.  Two other nice features are the two USB jumpers from the Notifier FirstVision to the cabinet.  This makes it nice for programming.  The other is the automatic locking solenoid for the enclosure door.  If there is a fire alarm condition, the Notifier FirstVision door will automatically unlock itself so that the fire department or first responders can easily go to work.

This annunciator boasts a 19" LCD display which not only shows the system condition, but the actual floor plans of the facility and the location of each device.  On top of the fire alarm devices, you can also display the location of items such as: roof access, gas shut off, locked doors, areas of refuge, HVAC shut off, etc.  This tool is unbelievably valuable to the first responders as it drastically reduces research time.  When the fire department responds to a fire in a facility with a Notifier ONYX series fire alarm system.




Here is some info to help you understand it size and current listings.

Cabinet Size:  24.63" W x 22.03" H x 3.47" D
Door Dimensions:  26" W x 22.75" H x 1.016 cm D
Power Requirements:  24VDC @ 3.0 amps, Regulated, filtered and non-resettable
UL/ULC Listed #S5697
MEA: 286-07-E
CSFM: 7300-1525:0103
FDNY: COA#6070

If you would like additional information on the ONYX First Vision touchscreen annunciator, contact Pyro-Comm Systems, Inc.  They are a NESCO affiliate for Notifier with extremely knowledgeable staff to answer your questions.

Make sure to join our Fire Alarms Online Facebook Group HERE.

Thursday, May 16, 2013

Notifier First Vision Touchscreen Fire Alarm Annunciator

Typical LED Graphic Annunciator for Fire Alarm Systems
Typical LED Graphic Annunciator
A while back Notifier (a division of Honeywell) came out with the FirstVision touchscreen annunciator for their fire alarm systems.  The Notifier First vision can be used on both standalone and networked fire alarm systems.  The FirstVision boasts a large 19" LCD screen with large buttons and on top of that, it was designed to work with the touch of a fireman's glove.  Unlike today's typical touchscreens found on the iPhone and Android phones, you do not need to touch it with bare skin.  Now the  Notifier FirstVision is not just any annunciator, it is a digital version of your standard graphic annunciator.  Typical LED style graphic annunciator depicting the entire facility can take up a lot of space are can get very expensive.  Another thing to mention on the typical graphic style annunciator is the labor intensive process to revise floor plans and device locations.  On the FirstVision you simply upload new floor plan backgrounds and relocate/add/delete devices.

The Notifier FirstVision touchscreen annunciator is packed with amazing features making it quite possibly the greatest piece of control equipment in today's fire alarm industry.  Some of the features include:

FirstVision by Notifier to be used with Oynx Series FACP
Firefighter using the Notifier FirstVision
  • 19" LCD Touchscreen
  • Windows Based CPU
  • Touchscreen works with gloves
  • Door automatically opens via solenoid in the event of a fire alarm condition
  • Mounts surface of flush
  • USB connections
  • Works on the NOTI-FIRE-NET vis NFN Gateway over Ethernet
  • Supports multiple Gateways for large network applications
  • Easy programming
Below is our YouTube video demonstration of the Notifier FirstVision touchscreen annunciator in action.  Take a look and let us know if you have any questions.