Fire Service Access Elevator FSAE Training Class

Fire Protection Education is hosting a 2 day online virtual seminar covering the new code revisions pertaining to fire service access elevators and occupant evacuation elevators. Read below for a quick overview of the class, pricing, contact info and how to signup.

Fire Service Access Elevator Introduction 

Fire Service Access Elevators or FSAEs were first required in the 2009 edition of the International Building Code or IBC Section 403.6 for all high-rise buildings over 120 feet. At that time only one Fire Service Access Elevator FSAE was required with 3,500lb capacity, serving all floors and sized to accommodate an ambulance stretcher per IBC Section 3002. This was just a standard electric passenger elevator (could not be hydraulic or freight) which was required to serve all floors of the building. This fire service access elevator could have a simplex operation or be a part of a group automatic operation and it required significant building protection around the elevator hoistway and the FSAE car per IBC Section 3007. The building protection features included: large lobbies (150SF in size with a minimum 8 feet dimension), protection of the hoistway and lobbies from Smoke, Heat, Fire and Water, hoistway lighting activated upon fire service activation, pathway survivability for control wires and a monitoring system to monitor the smoke and temperature conditions in the FSAE lobbies and Elevator Machine Room (EMR) or Elevator Control Room (ECR)

This one traction FSAE was just a regular passenger elevator or a service passenger elevator which could be used by the building occupants during the normal operation of the building. 

During fire and non-fire emergencies, the trained firefighters had the ability to choose this elevator for their firefighting emergency operation using Phase II in-car emergency operation. The responding firefighters had available information about the lobbies and EMR/ECR from the FCC and they could make a decision if they want to use this elevator or not to conduct their emergency firefighting and rescue operation. This one elevator had a much greater level of protection than all other elevators in the building and the firefighters were trained to select this specific elevator which was identified with a Fire Helmet symbol on the hoistway door jambs of the FSAE car.

Within the following 4 Code cycles of the IBC (2012, 2015, 2018 and 2021) another FSAE was added and since the 2012 IBC - TWO FSAEs are required in each high-rise building over 120 feet.  This additional FSAE was required for redundancy (in case the other FSAE was out of service or on inspection, etc.) but not for additional firefighting operation. Both FSAEs are required to be sized to accommodate an ambulance stretcher  per Section 3002 and both are required to have 3,500lb capacity.

What is changing with Fire Service Access Elevators?

There are many requirements included in the International Building Code (IBC) regarding these elevators however, no requirements are included for FSAEs in the A17.1/B44 Elevator Safety Code (current edition is 2019). 

The new 2022 edition of the A17.1/B44 will include provisions for the Fire Service Access Elevator FSAE controllers to provide a signal to the building electrical system to activate the FSAE hoistway lights upon Elevator Fire Service (FEO) activation. 

Significant changes are included in the 2021 edition of the IBC and detailed information about the FSAE Lobbies EMR/ECR temperature monitoring system via the building FA system is included in the 2019 edition of NFPA 72 Section 21.5 and A.21.5.

What is changing with Occupant Evacuation Elevators? 

A very significant change regarding the interface between the building fire alarm system and the Occupant Evacuation Elevators (OEE) is included in the 2022 edition of NFPA 72 Section 21.6 which will greatly affect the Fire Alarm system design and interface with the building elevator system.

Class Information

Class is a covered over two sessions as follows:

  • Session #1 (4 Hours): Thursday August 12, 2021 from 9:00am - 1:00pm PST
  • Session #2 (4 Hours): Friday August 13, 2021 from 9:00am - 1:00pm PST
  • Be sure to log in at 8:30am each day to verify connection
  • Course includes PDF color copy of class slides, completion certificate, color PDF flow chart for occupant evacuation elevator and fire alarm sequencing.
ICC Preferred Education Provider
  • ICC Course No 19708
  • Approved for 8 Hours - 0.8 ICC-CEUs
Course cost
  • General Public = $400.00
  • Active AHJs = $350.00
How to enroll